| LOADING COMPARISONS | |
| The internal architecture of VARILIGHT
transformers enables larger lamp loads to be dimmed because the load can
be calculated by adding the ratings of the lamps. With other compatible
transformers, the load must be calculated by adding the ratings of the
transformers. For example, a 400W VARILIGHT intelligent dimmer can be
loaded as follows:-
|
|
| With Other Compatible Transformers |
toUp to 5 x 60VA transformers with 5 x 50W lamps (max lamp load 250W) Up to 3 x 105VA transformers with 6 x 50W lamps (max lamp load 300W) |
| With VARILIGHT Transformers |
Up to 10 x 70VA transformers with 10 x 35W lamps (max lamp load 350W) Up to 4 x 105VA transformers with 8 x 50W lamps (max lamp load 400W) |
|
thus enabling up to 150 extra watts of lamp load to be dimmed with a 400W dimmer. |
|