V-Dim Standard Leading-Edge Dimmers (Product Codes H_ or T_)

See also: Grid Module Maximum Load Information for VARILIGHT PowerGrid System, Instruction Leaflets

Maximum load rating on product
Lighting Type
250W400W500W
(module)
1000W
(rotary, 1-way)
Incandescent250W400W500W1000W
Mains Halogen250W400W500W1000W
Low Voltage Halogen250W400W500WSee product label
See information on Transformer loading below
Low Voltage VARILIGHT Electronic Transformers250W400W500WSee product label
To calculate load, add the VA ratings of the transformers (not the wattage of the bulbs). Match the transformer rating closely to the lamp load (e.g. 50-70VA for a 50W bulb).
Other Brand Dimmable Electronic TransformersFor other brand dimmable electronic transformers, follow the guidelines above but with a maximum of 5 per dimmer circuit. Noise levels may vary depending upon the type and quantity of transformers used.
Minimum and Maximum LoadAt maximum loading some light bulbs may overload the dimmer because they present a higher load than their rating. If in doubt, reduce the load.
For best energy savings and performance, V-Dim dimmers should have a minimum load of 100W.
Wire-wound or Toroidal TransformersNot suitable for this application
LED LightingNot suitable for this application
Please use V-Pro or V-Com
Non-Dimmable Fluorescent Bulbs and TubesNot suitable for this application
Electric Motors (e.g. Fans)V-Dim dimmers are not suitable. Use the VARILIGHT Fan Regulator (product code H_10, 1-way circuits only), which also controls mains incandescent or halogen lamps on the same circuit.
Add the fan rating to the lamp ratings (e.g. a 100W fan plus 3 x 50W GU10 lamps = 250W) and keep within the product label.